//disable timestep
Timestep OFF
//get temperature for the first time
CALL CALCTEMP
VAR2 = VAR1
LABEL LOOP
//get temperature and put it into VAR1
CALL CALCTEMP
IF VAR1 != $VAR2 Then
//previous mesurement differs from current mesurement
IF VAR3 > 0005 Then
//time since last speech output is 5sec minimum
VAR3 = 0
CALL SAYTEMP
VAR2 = VAR1
ELSE
//time since previous speech output was too short
END IF
END IF
//wait 1 second between each mesurement (and increase counter VAR3)
WAIT 1000
VAR3 = VAR3 + 1
GOTO LOOP
//Sub Saytemperature: says the current temperature. (make connection)
SUB SAYTEMP
CONNECT TCP,127.0.0.1,9999
END SUB
//Sub Saytemperature: says the current temperature. (connection made)
SUB EVENT_CONNECTION_ESTABLISHED
//Speech Server running! clear error LED
CLEARIO 01
SEND "The temperature changed to $VAR1 degrees"
DISCONNECT
END SUB
//Sub Saytemperature: says the current temperature. (connection not possible)
SUB EVENT_CONNECTION_ERROR
//Speech Server not running! - set error LED
SETIO 01
END SUB
//Sub CalcTemp: calculates the current temperature (put into VAR1)
SUB CALCTEMP
TEXTVAR = "(($AD02*0.0196)/0.02)-24.1"
VAR1 = $CALC(TEXTVAR)